MiR logo

Safety configuration file

MiR1200 Pallet Jack is set up with the following safety configuration:

  • SICK configuration file : MiR1200 Pallet Jack SICK configuration HWx.x V6.0.5
  • Minimum supported software version : MiR Fleet Enterprise 1.2.0

Each configuration in the safety configuration file generates a checksum. The checksum will change if any modifications are made to the configuration.

The configuration file on your robot has the following checksums.

ComponentChecksum
Safety PLC0x60998570
Rear scanner function and network0xD824DC9
Rear scanner function0xBF2C8D4B
Front right scanner function and network0xBA96461D
Front right scanner function0xCBBA6E74
Front left scanner function and network0x58710226
Front left scanner function0xCF825C75

Checking the checksum

If you want to verify that the safety configuration file has not been modified, you can compare the current checksums. You will need to install the latest version of SICK's Safety Designer software to see the checksums.

To find the current checksums, follow these steps:

  1. Connect to your robot's network as described in Connect to the web-interface.

  2. Open SICK Safety Designer.

  3. Select Search for devices.

    Search for devices in the SICK Safety Designer tool.
  4. Drag all devices from the Device search window to the corresponding device in the Device overview window.

    When you are prompted to upload to the safety PLC, select No.

    Add devices to the active workspace.

    You can now read the current checksum values for each device configuration. If the values differ from the ones in Table 7.1, the safety configuration file has been modified from the original.

    The checksum values of the current configuration.